BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//wp-events-plugin.com//7.2.3.1//EN
BEGIN:VEVENT
UID:1251@x8ti.com
DTSTART;TZID=America/Toronto:20250414T090000
DTEND;TZID=America/Toronto:20250418T130000
DTSTAMP:20241219T203903Z
URL:https://x8ti.com/event/electrical-transient-analysis-program-etap-on-c
 ircuits-2/
SUMMARY:Electrical Transient Analysis Program (ETAP) on Circuits
DESCRIPTION:Introduction\nPower system equipment must withstand not only it
 s rated voltage but also short circuit voltages. A key issue related to vo
 ltages is arc flashing\, which primarily relies on short circuit and relay
  coordination studies. ETAP (Electrical Transient Analysis Program) is a w
 idely used software for power system analysis in various industries. This 
 training course focuses on power system modeling and analysis using ETAP s
 oftware to assess different power analysis models.\nLearning Objectives\nU
 pon completing this course by Xcelerate Training Institute\, participants 
 will be able to:\n\n 	Understand the significance of power system modeling
 .\n 	Comprehend the need for short circuit current calculation.\n 	Perform
  manual short circuit calculations using simple methods.\n 	Analyze motor 
 starting and acceleration.\n 	Determine switchgear breaking and making cap
 acities.\n 	Recognize the importance of arc flashing and relay coordinatio
 n studies for operational and safety purposes.\n 	Design S/S grid earthing
  using ETAP.\n 	Write test case simulations using ETAP software.\n 	Explor
 e the extensive capabilities of ETAP Power Station.\n\nTraining Methodolog
 y\nThis collaborative training program includes:\n\n 	Lectures\n 	Seminars
  and Presentations\n 	Group Discussions\n 	Assignments\n 	Case Studies and
  Functional Exercises Following the ‘Do-Review-Learn-Apply’ model.\n\n
 Benefits for Your Organization\nOrganizations can benefit from:\n\n 	Stayi
 ng ahead with a comprehensive overview of the Electrical Transient Analysi
 s Program (ETAP) on circuits.\n 	Assisting technical committees in creatin
 g\, publishing\, and revising standards related to ETAP.\n 	Utilizing exam
 ples and case studies to illustrate and ensure the material's applicabilit
 y to the organization.\n 	Gaining awareness and understanding of roles and
  responsibilities concerning ETAP.\n\nBenefits for You\nParticipants will 
 gain:\n\n 	Awareness of the latest developments in ETAP by studying new li
 terature and other sources.\n 	Access to a tailor-made academic program fo
 r technicians or equivalent workforce involved in ETAP.\n 	Training\, asse
 ssment\, and certification by experts in the ETAP domain.\n 	Opportunities
  to discuss and find solutions to issues encountered during their normal w
 orking activities.\n\nTarget Audience\nThis course is suitable for:\n\n 	C
 urrent ETAP users seeking a refresher.\n 	New ETAP users.\n 	Power enginee
 rs looking to enhance their skills using ETAP.\n\nCourse Outline\nOverview
  of ETAP\n\n 	Capabilities and Limitations of ETAP\n 	One-Line Diagram/One
 -Line View (OLV)\n 	Creating and merging revisions\, presentations\, and c
 onfigurations\n 	Scenario\, Study\, and Project Wizards\n 	Crystal Reports
  and Customizations\n\nElements of ETAP\n\n 	AC and DC Element Description
 s\n 	Load Modeling\n 	Electrical Systems Modeling and Fundamentals\n 	Load
  Flow (Balanced and Unbalanced) Analysis\n 	Load Flow and Cable Sizing\n\n
 Sizing &amp\; Fault Calculations\n\n 	Transformer Sizing\n 	Benefits of Ca
 lculated Short Circuit Currents\n 	Introduction to Fault Current Calculati
 ons\n 	Breaking and Making Currents\n 	Per Unit Systems\n 	Typical Values 
 of Positive\, Negative\, and Zero Phase Sequence Impedances\n\nPerform Cal
 culations Using Standard Techniques\n\n 	Manual Calculations of Isc by MVA
  Method\n 	Calculation of Isc by Impedance Method\n 	Calculation of Isc by
  Symmetrical Components\n 	Calculations as Defined and Recommended by IEC/
 ANSI Standards\n 	Fault Levels\n 	Switchgear/Fuse Rating\n 	Typical Cases 
 for Switchgear Sizing\n 	Relay Coordination and Arc Flashing Studies\n\nDa
 ta Collection\, Plotting &amp\; Modeling\n\n 	Data Collection Procedures\n
  	Plotting Time/Current Curves\n 	Relay Coordination Intervals\n 	Equipmen
 t Damage Curves for Cables\, Transformers\n 	System Modeling for Device Co
 ordination Study\n 	ETAP Star (Device Coordination/Selectivity)\n\nEarthin
 g &amp\; Acceleration Analysis\n\n 	System Earthing (Solid\, Resistance\, 
 and Reactance or Ungrounded Systems)\n 	Substation Grounding Grid Design a
 nd Calculations\n 	Motor Parameter Estimation\n 	Motor Acceleration Analys
 is (Dynamic and Static)\n 	Test Simulation Cases using ETAP\n 	Course Eval
 uations and Summary\n\nIntroduction to ETAP Software\n\n 	Introduction to 
 ETAP Software\n 	Creating Single Line Diagrams in ETAP\n 	Adding Templates
  and Parameters to SLD\n\nIntroduction to ETAP Software\n\n 	Load Flow Ana
 lysis\n 	Report Manager and Transformer Overloading\n 	Composite Network i
 n ETAP\n 	Short Circuit Analysis\n 	Arc Flash Analysis\n\nIntroduction to 
 ETAP Software\n\n 	Motor Acceleration Static Study\n 	Motor Acceleration S
 tudy Dynamic\n 	Motor Acceleration Study with VFD\n\nIntroduction to ETAP 
 Software\n\n 	Cable Pulling System\n 	Cable Ampacity Calculation with Unde
 rground Raceway System\n\n&nbsp\;
ATTACH;FMTTYPE=image/jpeg:https://x8ti.com/wp-content/uploads/2024/12/4f42
 990d-ad58-48fc-aed6-e547d8c5caf4.jpg
CATEGORIES:Electrical Engineering
LOCATION:Boston Training Courses\, Boston Harbor Hotel\, Boston\, USA\, Uni
 ted States
X-APPLE-STRUCTURED-LOCATION;VALUE=URI;X-ADDRESS=Boston Harbor Hotel\, Bosto
 n\, USA\, United States;X-APPLE-RADIUS=100;X-TITLE=Boston Training Courses
 :geo:0,0
END:VEVENT
BEGIN:VTIMEZONE
TZID:America/Toronto
X-LIC-LOCATION:America/Toronto
BEGIN:DAYLIGHT
DTSTART:20250309T030000
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
END:DAYLIGHT
END:VTIMEZONE
END:VCALENDAR